Compact Threaded Connection

The ZT-100TEG S-Series is a compact water-in-TEG monitor with threaded process connections, designed for installation on glycol skids, regeneration units, and sample points where space is limited. The screw-in design allows quick installation in existing tapping points without pipeline modification.

Available with 1" and 1.5" NPT or BSP connections, the S-Series is ideal for monitoring glycol quality at multiple points throughout the dehydration circuit without the cost and footprint of full-bore instruments.

ZT-100TEG S-Series Water in TEG Monitor

Key Features

Compact Design

Small form factor ideal for glycol skids, regeneration units, and process connections with limited space.

TEG-Optimised

Calibrated for the dielectric properties of triethylene glycol across the full range of water loading.

Threaded Connections

1" and 1.5" NPT or BSP threads for direct installation into existing tapping points without welding.

Hazardous Area Certified

ATEX and IECEx certification for Zone 1 and Zone 2 installations at gas processing facilities.

Robust Construction

316L stainless steel wetted parts and IP67 rated enclosure for outdoor gas plant environments.

Standard Communication

4-20mA analog output and Modbus RTU digital communication for DCS, SCADA, and PLC integration.

Technical Specifications

Measurement Performance

MediumTriethylene glycol (TEG)
Measurement Range0–100%
Resolution0.001%
Accuracy0.01%
Repeatability0.01% Absolute
Sensitivity0.01%

Mechanical

Nominal Sizes1″ to 12″
Pressure Rating150#, 300#, 600#
Process Temperature+120°C (High Temp Option available)
Wetted Material (Sensor)SS316L (Optional Duplex, Inconel or other steels)
Wetted Material (Spool)SS316L (other material available)
Seals & InsulatorsPEEK
Process ConnectionANSI, DIN, JIS

Electronics

Principle of OperationHigh Frequency Digital Capacitance
Output Signal4–20mA
Digital CommunicationModbus RTU (RS-485)
Power Supply24VDC (4-wire)
Power Consumption2W Max
Measurement Rate1000 per second
Ambient Temperature–20°C to +60°C
Ingress ProtectionIP66

Applications

Glycol Skid Monitoring

Compact installation on packaged glycol dehydration skids where space and weight are constrained.

Regeneration Units

Monitor glycol quality at the reboiler inlet and outlet to verify regeneration performance.

Sample Point Monitoring

Install in existing sample connections for continuous glycol quality monitoring without additional piping.

Multi-Point Monitoring

Cost-effective installation at multiple locations in the glycol circuit for complete system visibility.

Configure Your ZT-100TEG S-Series

Specify your connection size, thread type, and process conditions and we will provide a complete quotation for your glycol dehydration application.